C55 Cross‑linked ETFE Insulated Single‑Core Wire
Product performance: Excellent dielectric insulation, high voltage resistance, low high-frequency loss, non-hygroscopic, high insulation resistance.
| AWG | Conductor Stranding (N/AWG) | Conductor Stranding (N/mm) (Tol. ±0.008mm) |
Conductor OD (mm) | Insulation Thickness (mm) | Insulation Diameter (mm) | Resistance (plated Cu) (Ω/km) | Resistance (plated Cu alloy) (Ω/km) |
| 28 | 7/36 | 7/0.12 | 0.36 | 0.15 | 0.69±0.05 | 209 | 244 |
| 26 | 19/38 | 19/0.10 | 0.5 | 0.15 | 0.81±0.05 | 126 | 147 |
| 24 | 19/36 | 19/0.12 | 0.6 | 0.15 | 0.94±0.05 | 79.8 | 93.2 |
| 22 | 19/34 | 19/0.16 | 0.8 | 0.15 | 1.09±0.05 | 49.6 | 57.4 |
| 20 | 19/32 | 19/0.20 | 1 | 0.15 | 1.27±0.05 | 30.2 | 35.1 |
| 18 | 19/30 | 19/0.23 | 1.15 | 0.15 | 1.52±0.08 | 19 | 22.3 |
| 16 | 19/29 | 19/0.28 | 1.4 | 0.15 | 1.73±0.08 | 14.8 | -- |
| 14 | 19/27 | 19/0.37 | 1.85 | 0.15 | 2.16±0.08 | 9.5 | -- |
| 12 | 19/25 | 37/0.32 | 2.24 | 0.15 | 2.62±0.08 | 6.2 | -- |